Matching wattage and lumens do not guarantee the same light on a table or wall. Beam angle helps you judge whether a fitting creates a small accent or broader coverage. Choose it around the object, distance and task rather than assuming wider is always better.
Start by comparing Luminance’s track lighting systems and recessed lights. The following guidance explains optics; it does not imply that every fitting in these categories is available with all four beam angles.
1. What does beam angle mean?
Beam angle usually describes the full angle between directions where luminous intensity falls to half the maximum intensity in the beam. It is not a hard edge: light may still be visible outside that angle. Check that manufacturers use comparable definitions when comparing fittings.
The angle does not describe the complete distribution. Two lights marked 36° can differ in uniformity, centre intensity and spill light. For elongated or asymmetric optics, consult the intensity distribution and photometric file rather than relying on a single number.

2. 24°: highlight an object, not the entire room
A narrow beam is worth considering for artwork, a textured wall detail or an object on a shelf. It helps distinguish an accent from its background but needs careful aiming. If the light patch is smaller than the object, its edges may remain noticeably darker.
With a 24° beam aimed perpendicular to a surface 2 m away, the geometric diameter is approximately 0.85 m. This estimates size, not an evenly illuminated area. For glazed artwork, also check reflections of the source from the viewer’s usual position.
3. 36°: local lighting with broader coverage
36° can be considered for a group of objects, a small section of worktop or a larger accent. At the same 2 m distance, the geometric estimate is about 1.30 m. Moving from 24° to 36° already makes a substantial difference to coverage.
With track lighting, individual fittings can be aimed separately. However, an adjustable head does not automatically have interchangeable optics. A replacement lens or zoom mechanism must be explicitly supported by the exact model.
4. 60° and 100°: covering a wider area
60° is worth considering for a broader local area or as part of general lighting using several fittings. Its geometric diameter at 2 m is around 2.31 m. For a workplace, assess illuminance on the surface and shadows cast by the user, not just patch size.
100° offers broader coverage again: approximately 4.77 m under the same conditions. This does not mean that one fitting evenly lights a room nearly five metres wide. Distance and incidence angle vary towards the edges, while furniture, finishes and distribution affect the outcome.
A wide beam is not automatically glare-free. Comfort also depends on source visibility, brightness and fitting design. Dedicated optics may be more useful for a wall or work surface than simply choosing a larger angle.
5. Measure distance to the target surface
For a circular, symmetric beam aimed perpendicular to a flat surface, estimate diameter with D = 2 × H × tan(θ / 2). H is the distance from the light centre to the target surface; θ is the full angle. This formula does not calculate lux or account for reflections.
At 36°, a distance of 1 m gives a diameter of about 0.65 m; at 2 m it is about 1.30 m. The same fitting therefore covers different areas on a table and floor. Tilting produces an elongated patch, so the simple circular estimate no longer describes its shape.

6. A checklist before choosing
Define the task first: highlighting an object, lighting a work surface or creating background light. Then compare optics, light output and placement together. A project with several lighting zones benefits from a photometric check.
- Measure to the artwork, table or floor — the actual surface you want to illuminate.
- Compare the object’s size with estimated beam coverage and check its edges.
- Assess aiming, beam overlap, shadows and reflections from normal viewing positions.
- Check the exact article’s beam angle, light output, adjustment and compatible lenses.
- Do not choose fitting spacing from beam diameter alone: check uniformity using photometry.
- For recessed fittings, separately check installation dimensions and operating conditions.
Choose lighting for the task, not just the wattage
Explore the Luminance catalogue. For a more focused discussion, prepare a plan, dimensions of the object to be lit and its distance from the fitting.
Explore the catalogue